PT. Indira Dwi Mitra - Fabrikasi boiler dan thermal oil heater Indonesia

olympia gas/oil burner

Light Oil Burners – TC Series

Owing to their compact design, these burners are especially applicable for Hot Water Boiler, Heating Unit and such types of applications.  This series adopts higher pressure fan to get more air.  Burners come with Diaphragm oil pump for longer life.

Light Oil Burners – OM Series

This series comprises of small and medium sized burners that are being used for smaller equipment with a relatively high combustion chamber pressure.  This series has great freedom of installation position – horizontal, vertical or in other angles, and the burner head can be removed and reinstalled with ease to facilitate maintenance.

Light Oil Burners – LT Series

This series comprises of small, medium and large sized burners. Low noise and high performance make them suitable for varied applications like Incinerators, Driers, Hot Water Boilers and so on…  Hinged design of the burner head in medium and large sized models of this series makes cleaning and inspection a lot easier.

Furnace Oil Burners – LB Series

This series includes medium to large sized burners suitable for heavy oils.  The fuel is heated while being circulated to the nozzle, providing excellent ignition and stable combustion.

Gas Burners – KSY Series

This series burner can fire both LNG and LPG. Compact design of these burners provide freedom of installation position – horizontal, vertical or in other angles. These are widely used in heating equipments.

Gas Burners – GOM Series

This series burner can fire both LNG and LPG. Very high performance and “Direct ignition” are characteristic features of these burners.  Burners come with single stage / two stage Dungs / Honeywell / CKD gas valve. The Flame tube and diffuser disc are of SS.  High fan pressures – even at full loads pressure does not drop drastically

Gas Burners – GLT Series

This series comprises of Gun type burners with Cast Aluminium housing.  Burners are fitted with rotary flange for easy maintenance.  Good adaptability and high P-Q feature are characteristic features of these burners.

Gas Burners – AG Series

This series has essentially no danger of a backfire as it employs an external mixture combustion method.  This ensures stable combustion in a wide range of applications.  The burner and control are designed in compliance with the safety requirements for the gas appliances and equipment.  Well arranged layout of the burner head, fan and control results in a compact construction to enable effective use of a small space.  A strong pilot flame ensures a secure ignition of the main gas. Both the main and the pilot burner are so designed as to allow simple removal and reinstallation, thus providing ease of inspection, cleaning and other maintenance.

Salient Features
  • Manufactured under high quality requirement of Japan which calls for continuously operating pilot gas burner with dedicated gas train
  • On / Off, Two stage and Proportional control burners are available
  • Fan motor can be bypassed easily without major changes in burner wiring / operation
  • Can fire LPG and also LNG without any capacity derating
  • Higher capacity burners come with UV scanner

Dual Fuel Burner – RBX Series

This category of burner is capable of firing dual fuels namely light oil or LPG/LNG.  Selection of fuel is enabled by a change over switch.

Salient Features
  • Suitable for firing either light oil or LPG / LNG
  • Switching over from one fuel to another is made simpler by a change over switch
  • Oil pumps used are always compatible for kerosene use
  • Fully prewired control panel comes along with the burner
Specification
MODEL OUTPUT KCAL/HR OUTPUT KW CONTROL MOTOR WATT / PHASE
RBX – 30 300000 350 ON – OFF 400 / 3Ø
RBX – 50 500000 588 ON – OFF 1000 / 3Ø
RBX – 30W 300000 350 TWO STAGE 400 / 3Ø
RBX – 50W 500000 588 TWO STAGE 1000 / 3Ø
RBX – 80W 800000 941 TWO STAGE 1500 / 3Ø
RBX – 140W 1400000 1647 TWO STAGE 2200 / 3Ø
RBX – 30P 300000 350 PROPORTIONAL 400 / 3Ø
RBX – 50P 500000 588 PROPORTIONAL 1000 / 3Ø
RBX – 80P 800000 941 PROPORTIONAL 1500 / 3Ø
RBX – 140P 1400000 1647 PROPORTIONAL 2200 / 3Ø

Fuel Input Conditions:

  • Light oil: Flooded suction
  • LPG: 280 mm WC (28 mBar)
  • LNG: 200 mm WC (20 mBar) through filters
Specification
MODEL OUTPUT KCAL/HR OUTPUT KW CONTROL MOTOR WATT / PHASE
AG – 5S 50000 59 ON – OFF 40 / 1Ø
AG – 10S 100000 118 ON – OFF 150 / 1Ø
AG – 15S 150000 176 ON – OFF 250 / 1Ø
AG – 25S 250000 294 ON – OFF 400 / 3Ø
AG – 30S 300000 353 ON – OFF 400 / 3Ø
AG – 40S 400000 471 ON – OFF 750 / 3Ø
AG – 45S 450000 529 ON – OFF 750 / 3Ø
AG – 60S 600000 706 ON – OFF 1000 / 3Ø
AG – 5WS 50000 59 TWO STAGE 40 / 1Ø
AG – 10WS 100000 118 TWO STAGE 150 / 1Ø
AG – 15WS 150000 176 TWO STAGE 250 / 1Ø
AG – 25WS 250000 294 TWO STAGE 400 / 3Ø
AG – 30WS 300000 353 TWO STAGE 400 / 3Ø
AG – 40WS 400000 471 TWO STAGE 750 / 3Ø
AG – 45WS 450000 529 TWO STAGE 750 / 3Ø
AG – 60WS 600000 706 TWO STAGE 1000 / 3Ø
AG – 80WS 800000 941 TWO STAGE 1500 / 3Ø
AGP – 5S 50000 59 PROPORTIONAL 40 / 1Ø
AGP – 10S 100000 118 PROPORTIONAL 150 / 1Ø
AGP – 15S 150000 176 PROPORTIONAL 250 / 1Ø
AGP – 25S 250000 294 PROPORTIONAL 400 / 3Ø
AGP – 30S 300000 353 PROPORTIONAL 400 / 3Ø
AGP – 40S 400000 471 PROPORTIONAL 750 / 3Ø
AGP – 45S 450000 529 PROPORTIONAL 750 / 3Ø
AGP – 60S 600000 706 PROPORTIONAL 1000 / 3Ø
AGP – 80S 800000 941 PROPORTIONAL 1500 / 3Ø
AGP – 100S 1000000 1176 PROPORTIONAL 1500 / 3Ø
AGP – 150S 1500000 1765 PROPORTIONAL 2200 / 3Ø
AGP – 200S 2000000 2353 PROPORTIONAL 3700 / 3Ø
AGP – 250S 2500000 2941 PROPORTIONAL 5500 / 3Ø
AGP – 300S 3000000 3529 PROPORTIONAL 7500 / 3Ø

Fuel Input Conditions:

  • LPG: 280 mm WC (28 mBar)
  • LNG: 200 mm WC (20 mBar) through filters
Dimension
Gas Burners - AG Series Dimension
Model A B C D E F φG H I J K
AG-5S 250 270 270 275 115 100 101 200 180 4-φ10
AG-10S 270 277 275 290 120 100 114 200 180 4-φ10
AG-15S 362 293 360 365 135 100 140 270 240 8-φ12
AG-25S 397 293 410 415 135 100 160 270 240 8-φ12
AG-30S 425 305 440 470 135 120 180 270 240 8-φ12
AG-40S 460 305 480 505 135 120 180 270 240 8-φ12
AG-45S 460 305 480 505 135 120 180 270 240 8-φ12
AG-60S 505 435 540 540 155 120 216 340 310 8-φ12
AGP-80S 576 450 570 640 175 150 240 380 350 240 12-φ12
AGP-100S 576 460 570 650 182 150 260 400 364 240 12-φ12
AGP-150S 626 490 580 710 225 180 290 450 410 240 12-φ13
AGP-200S 676 510 600 760 245 180 330 490 450 260 12-φ13
AGP-250S 910 525 640 1020 260 200 360 520 480 280 12-φ13
AGP-300S 950 550 660 1050 290 200 410 580 544 300 12-φ13

NOTE : Dimensional values above are all standard specifications. If you need special specifications, please ask us for the drawing separately. Piping dimensions vary a
little to the kind of gas.

Salient Features
  • High fan pressures – even at full loads pressure does not drop drastically
  • Fan motor can be bypassed easily without major changes in burner wiring / operation
  • Comes with single stage / two stage Dungs / Honeywell / CKD gas valve
  • Flame tube and diffuser disc are of SS
  • Igniter is kept “on” for 16 seconds
  • Can fire LPG and also LNG without any capacity derating
  • Fully prewired control panel comes along with the burner
Download Gas Burners GLT Series Brochure  Submit

Specification
MODEL OUTPUT KCAL/HR OUTPUT KW CONTROL MOTOR WATT / PHASE
GLT – 51W 500000 588 TWO STAGE 400 / 3Ø
GLT – 61W 600000 705 TWO STAGE 750 / 3Ø
GLT – 81W 800000 941 TWO STAGE 1000 / 3Ø

Fuel Input Conditions:

  • LPG: 280 mm WC (28 mBar)
  • LNG: 200 mm WC (20 mBar) through filters

 

PQ Features chart and flame dimensions
Gas Burner - GLT Series- PQ Features chart and flame dimensions
TYPE A B C D E F G
GLT – 51W Ø 140 150 937 435 522 4 – Ø 12 Ø 230
GLT – 61W Ø 140 150 937 435 522 4 – Ø 12 Ø 230

Salient Features
  • High fan pressures – even at full loads pressure does not drop drastically
  • Fan motor can be bypassed easily without major changes in burner wiring / operation
  • Comes with single stage / two stage Dungs / Honeywell / CKD gas valve
  • Flame tube and diffuser disc are of SS
  • Igniter is kept “on” for 16 seconds
  • Can fire LPG and also LNG without any capacity derating
  • Fully prewired control panel comes along with the burner
Download Gas Burners GOM Series Brochure  Submit

Specification
MODEL OUTPUT KCAL/HR OUTPUT KW CONTROL MOTOR WATT / PHASE
GOM – ON 70000 82 ON – OFF 100 / 1Ø
GOM – 1N 100000 116 ON – OFF 150 / 1Ø
GOM – 2N 200000 233 ON – OFF 250 / 1Ø
GOM – 3N 300000 350 ON – OFF 400 / 3Ø
GOM – 4N 400000 467 ON – OFF 400 / 3Ø
GOM – 1NWM 100000 116 TWO STAGE 150 / 1Ø
GOM – 2NWM 200000 233 TWO STAGE 250 / 1Ø
GOM – 3NWM 300000 350 TWO STAGE 400 / 3Ø
GOM – 4NWM 400000 467 TWO STAGE 400 / 3Ø

Fuel Input Conditions:

  • LPG: 280 mm WC (28 mBar)
  • LNG: 200 mm WC (20 mBar) through filters)
Dimension
Model A B C D E F G
GOM-0N φ76 100 325 314 359 8-φ11 φ135/φ150
GOM-1N φ88 100 429 384 358 4-φ11 φ150
GOM-2N φ114 120 458 426 404 4-φ12 φ190
GOM-3N φ140 150 664 524 468 4-φ12 φ240
GOM-4N φ140 150 664 524 468 4-φ12 φ240
GOM-0NWM φ76 100 502 351 435 8-φ11 φ135/φ150
GOM-1NWM φ88 100 592 366 450 4-φ11 φ150
GOM-2NWM φ114 120 700 425 496 4-φ12 φ190
GOM-3NWM φ140 150 700 425 550 4-φ12 φ240
GOM-4NWM φ140 150 731 407 550 4-φ12 φ240
Dimension Capacity Curve
Gas Burner - GOM Series- Dimension & Capacity Curve

Salient Features
  • Comes with single stage / two stage Dungs gas valve
  • High fan pressures – even at full loads pressure does not drop drastically
  • Fan motor can be bypassed easily without any major change in the burner wiring / operation
  • Can be fixed in any orientation (360 deg)
  • Can fire LPG and also LNG without any capacity derating
  • Flame tube and diffuser are of SS
Download Gas Burners KSY Series Brochure  Submit

Specification
MODEL OUTPUT KCAL/HR OUTPUT KW CONTROL MOTOR WATT / PHASE
KSY – 1.6 25000 30 ON – OFF 40 / 1Ø
KSY – 2.3 35000 41 ON – OFF 80 / 1Ø

Fuel Input Conditions:

  • LPG: 280 mm WC (28 mBar)
  • LNG: 200 mm WC (20 mBar) through filters
Dimension
Gas Burner - KSY Series - Dimension
Model A B C D E F
KSY-1.6 Ø89.1 100 236 288 415 345
KSY-2.3 Ø89.1 100 236 288 415 345

Salient Features
  • There are no bakelite or plastic components in the burner (exposed to temperatures) making it suitable for operation under heat and pressure
  • Unique hinge design of the burner helps a lot during maintenance
  • Direct immersion electrical heater which responds very quickly is used
  • Pressure gauge, temperature gauge come fitted along with the burner
  • Two numbers of oil hose each 1 m long, one number of oil suction filter (online cleaning type) come along with the burner
  • No separate dedicated return oil line is required to be taken to service tank to carry return oil from burner
  • Prewired panel comes along with the burner. Only 3 phase power supply and single phase supply from controller needs to be given to the panel. This will avoid the cost of extra panel and interconnecting wiring
  • Burner flame tube and diffuser are made of SS
  • Hooter / Alarm provision to indicate burner TRIP conditions is available in the burner panel
  • On / Off, Two stage and Proportional control burners are available
Download Furnace Oil Burners LB Series Brochure  Submit

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
LB – 20 8 – 20 235 ON – OFF 400 / 3Ø
LB – 35 12 -35 412 ON – OFF 400 / 3Ø
LB – 61 30 – 60 706 ON – OFF 750 / 3Ø
LB – 35W 12 – 35 412 TWO STAGE 400 / 3Ø
LB – 61W 30 – 60 706 TWO STAGE 750 / 3Ø
LB – 81W 40 – 80 941 TWO STAGE 750 / 3Ø
LB – 120W 60 – 120 1412 TWO STAGE 1500 / 3Ø
LB – 150W 70 – 150 1765 TWO STAGE 2200 / 3Ø
LB – 200 W 100 – 200 2353 TWO STAGE 3700 / 3Ø
LB – 250W 120 – 240 2824 TWO STAGE 3700 / 3Ø
LB – 350W 150 – 300 3529 TWO STAGE 5500 / 3Ø
LBP – 35 12 – 35 412 PROPORTIONAL 400 / 3Ø
LBP – 61 30 – 60 706 PROPORTIONAL 750 / 3Ø
LBP – 81 40 – 80 941 PROPORTIONAL 750 / 3Ø
LBP – 120 60 – 120 1412 PROPORTIONAL 1500 / 3Ø
LBP – 150 70 – 150 1765 PROPORTIONAL 2200 / 3Ø
LBP – 200 100 – 200 2353 PROPORTIONAL 3700 / 3Ø
LBP – 250 120 – 240 2824 PROPORTIONAL 3700 / 3Ø
LBP – 350 150 – 300 3529 PROPORTIONAL 5500 / 3Ø
LB – 301T* 50 – 280 3294 TWO STAGE 5500 / 3Ø
LB – 401T* 100 – 350 4118 TWO STAGE 7500 / 3Ø
LBP – 301T* 50 – 280 3294 PROPORTIONAL 5500 / 3Ø
LBP – 401T* 100 – 350 4118 PROPORTIONAL 7500 / 3Ø
LBP – 600T* 300 -650 7647 PROPORTIONAL 15000 / 3Ø
LBP – 1000T* 450 – 850 10000 PROPORTIONAL 22000 / 3Ø

* – Indicates Turbo fan for higher back pressureFuel Input Conditions:

  • 80 – 100 deg C at 0.5 Bar pressure filtered through 120 mesh
Dimension
Furnace Oil Burners - LB Series - Dimension
Model A B C D E F G H I J (K) L M
LB-35(W) 152 120 310 160 590 150 115 422 230 205 435 195 222
LB-61(W) 152 120 335 162 617 155 115 422 254 254 508 195 224
LB-81W 152 120 360 287 767 173 136 464 300 260 560 210 240
LB-120W 162 150 405 287 842 200 158 530 350 380 730 210 250
LB-150W 190 150 477 305 932 240 176 582 460 380 840 240 290
LB-200W 190 150 477 305 932 240 176 582 460 446 906 240 290
LB-250W 215 190 565 313 1068 280 180 650 500 485 985 305 345
LB-350W 215 190 565 313 1068 280 180 650 500 495 995 305 345
Dimension
Furnace Oil Burners - LB Series - Dimension
Model A B C D E F G H I J (K) L M
LBP-35 152 120 310 205 630 150 115 480 350 205 555 195 222
LBP-61 152 120 335 205 660 155 115 480 375 254 629 195 224
LBP-81 152 120 360 225 735 173 136 530 385 260 645 210 240
LBP-120 162 150 405 238 867 200 158 550 414 380 794 210 250
LBP-150 190 150 477 238 895 240 176 580 450 380 830 240 290
LBP-200 190 150 477 238 895 240 176 580 450 446 896 240 290
LBP-250 215 190 565 313 972 280 180 650 500 485 985 305 345
LBP-350 215 190 565 313 972 280 180 650 500 495 995 305 345

Salient Features
  • No return oil line (only one hose is used)
  • Solenoid valve with coil comes separately in the copper line. Thus minimizes replacement costs
  • Pumps are always kerosene compatible ones
  • Igniter is kept “on” for 16 seconds
  • Oil hose and pressure gauge come along with the burner
  • Air lock removal valve is provided in the oil line
  • Fan motor can be bypassed easily without major changes in the burner wiring / operation
  • Two stage burners are available with air damper motor. Fully prewired panel comes along with the burner
  • Diffuser is of SS
  • Proportional control / Continuous modulation burners are also available from 10 lph onwards
Download Light Oil Burners - LT Series Brochure  Submit

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
LT – 3 4 -10 100 ON -OFF 150 / 1Ø
LT – 20 6 – 20 200 ON -OFF 250 / 1Ø
LT – 30 10 – 30 300 ON -OFF 250 / 1Ø
LT – 35 12 – 35 350 ON -OFF 250 / 3Ø
LT – 61 20 – 60 600 ON -OFF 750 / 3Ø
LT – 35W 12 – 35 350 TWO STAGE 250 / 3Ø
LT – 61W 20 – 60 600 TWO STAGE 750/ 3Ø
LT – 81W 30 – 80 800 TWO STAGE 750 / 3Ø
LT – 120W 40 – 120 1200 TWO STAGE 1500 / 3Ø
LT – 150W 50 – 150 1500 TWO STAGE 2200 / 3Ø
LT – 200W 70 – 200 2000 TWO STAGE 3700 / 3Ø
LT – 250W 80- 250 2500 TWO STAGE 3700 / 3Ø
LT – 350W 120 – 350 3500 TWO STAGE 5500/ 3Ø
Dimension
Light Oil Burners - LT Series Dimension
Model A B C D E F G H I J (K) L M
LT-35 152 120 310 160 590 150 115 422 230 205 435 195 222
LT-61 152 120 335 162 617 155 115 422 238 254 492 195 224
LT-61W 152 120 335 291 746 155 115 422 238 254 492 195 224
LT-81 152 120 360 287 767 173 136 464 271 260 531 210 240
LT-120 162 150 405 287 842 200 158 530 317 380 697 210 250
LT-150 190 150 477 305 932 240 176 582 354 380 734 240 290
LT-200 190 150 477 305 932 240 176 582 354 446 800 240 290
LT-250 215 190 565 313 972 280 180 650 365 485 850 305 345
LT-350 215 190 565 313 972 280 180 650 365 495 860 305 345

Specification

MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
LTP – 35 10- 35 350 PROPORTIONAL 250 / 3Ø
LTP – 61 20 – 60 600 PROPORTIONAL 750/ 3Ø
LTP – 81 30 – 80 800 PROPORTIONAL 750 / 3Ø
LTP – 120 40 – 120 1200 PROPORTIONAL 1500 / 3Ø
LTP – 150 50 – 150 1500 PROPORTIONAL 2200 / 3Ø
LTP – 200 70 – 200 2000 PROPORTIONAL 3700 / 3Ø
LTP – 250 80 – 250 2500 PROPORTIONAL 3700 / 3Ø
LTP – 350 120 – 350 3500 PROPORTIONAL 5500/ 3Ø
LT – 301T* 50 – 280 2800 TWO STAGE 5500 / 3Ø
LT – 401T* 100 – 350 3500 TWO STAGE 7500 / 3Ø
LTP – 301T* 50 – 280 2800 PROPORTIONAL 5500 / 3Ø
LTP 401T* 100 – 350 3500 PROPORTIONAL 7500 / 3Ø
LTP – 600T* 300 – 650 6500 PROPORTIONAL 15000 / 3Ø
LTP – 1000T* 450 – 850 8500 PROPORTIONAL 22000 / 3Ø

* – Indicates Turbo fan for higher back pressure.

Dimension
Light Oil Burners - LT Series Dimension
Model / Mark A B C D E F G H I J (K) L M
LTP-61 152 120 335 205 660 155 115 480 375 254 629 195 224
LTP-81 152 120 360 225 735 173 136 530 385 260 645 210 240
LTP-120 162 150 405 238 867 200 158 550 414 380 794 210 250
LTP-150 190 150 477 238 895 240 176 580 450 380 830 240 290
LTP-200 190 150 477 238 895 240 176 580 450 446 896 240 290
LTP-250 215 190 565 313 972 280 180 650 500 485 985 305 345
LTP-350 215 190 565 313 972 280 180 650 500 495 995 305 345

Fuel Input Conditions:

  • Flooded suction
Salient Features
  • No return oil line (only one hose is used)
  • Solenoid valve with coil comes separately in the copper line. Thus minimizes replacement costs of spares
  • Pumps used are always kerosene compatible ones
  • Igniter is kept “on” for 16 seconds
  • High fan pressures – even at full loads pressure does not drop drastically
  • Oil hose and pressure gauge come along with the burner
  • Air lock removal valve is provided in the oil line
  • Fan motor can be bypassed easily without any major change in the burner wiring / operation
  • Diffuser is of SS

Duct Burners – CD Series

This series includes burners with compact design and easy maintenance.  The proportional control method is adopted for the adjustment of the gas combustion to ensure stable operation and proper temperature control.

Salient Features

Safe Design:

  • No possibility of back fire due to adoption of pre-mixture combustion method
  • Design safety is based on The Technology Indication on combustion given by the Japan Gas Association

Space saving and easy maintenance:

  • The blower for combustion and the gas piping etc are installed on the upper part of the main body and thus it contributes to space saving
  • The window to observe combustion condition and the inspection door are installed. The latter is of hinged type, enabling easy inspection and maintenance of inside part

Stable operation and temperature control: 

  • The burner possesses a strategic construction which gives an excellent stability of combustion
  • The proportional control method is adopted for the adjustment of the gas combustion and proper temperature control becomes available. (On-Off & High – low – off control modes are also available)
Specification
MODEL Capacity (Kcal/h) Fuel consumption (m3/h)- LPG Fuel gas pressure (mmWC)-LPG Voltage / Phase Motor KW Duct cross section (mm) Combustion method Connecting pipe diameter(inch)-LPG Turn down ratio
CD-50PW 50,000 2.1 280 220 v / 1Ø 0.25 500*320 PRE-MIXING 1/2 1:3
CD-100PW 100,000 4.2 280 220 v / 1Ø 0.25 700*500 1/2 1:5
CD-200PW 200,000 8.3 280 400 v / 3Ø 0.4 950*700 1/2 1:10
CD-300PW 300,000 12.5 280 400 v / 3Ø 0.75 1100*900 3/4 1:10
CD-400PW 400,000 16.7 280 400 v / 3Ø 0.75 1300*1000 1 1:10
CD-500PW 500,000 20.8 280 400 v / 3Ø 1.5 1500*1100 1-1/4 1:10
CD-600PW 600,000 25 280 400 v / 3Ø 1.5 1100*900 1-1/2 1:10
CD-700PW 700,000 29.2 280 400 v / 3Ø 2.2 1400*1100 1-1/2 1:10
CD-800PW 800,000 33.3 280 400 v / 3Ø 2.2 1400*1100 2 1:10
CD-900PW 900,000 37.5 280 400 v / 3Ø 3.7 1550*1150 2 1:10
CD1000PW 1,000,000 41.7 280 400 v / 3Ø 3.7 1550*1150 2 1:10

Fuel Input Conditions:

  • LPG: 280 mm WC (28 mBar)
Dimension
Duct Burners - CD Series - Dimension
Model A B C D E F G H I J (LPG)
CD-50PW 650 470 1000 500 320 75 75 920 335 690
CD-100PW 850 650 1000 700 500 75 75 1100 425 870
CD-200PW 1100 850 1000 950 700 75 75 1300 525 1070
CD-300PW 1250 1050 1200 1100 900 75 75 1540 625 1270
CD-400PW 1450 1150 1300 1300 1000 75 75 1680 675 1390
CD-500PW 1650 1250 1400 1500 1100 75 75 1780 725 1490
CD-600PW 1300 1100 1400 1100 900 100 100 1700 650 1620
CD-700PW 1600 1300 1500 1400 1100 100 100 1900 750 1820
CD-800PW 1600 1300 1500 1400 1100 100 100 1900 750 1820
CD-900PW 1750 1350 1800 1550 1150 100 100 2070 775 1870
CD-1000PW 1750 1350 1800 1550 1150 100 100 2070 775 1930

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
OM – 1N 4 – 12 120 ON -OFF 150 / 1Ø
OM – 2N 8 – 24 240 ON -OFF 250 / 1Ø
OM – 3N 12 – 36 360 ON -OFF 250 / 1Ø
OM – 4N 16 – 48 480 ON -OFF 400 / 3Ø
OM – 1NWM 4 – 12 120 TWO STAGE 150 / 1Ø
OM – 2NWM 8 – 24 240 TWO STAGE 250 / 1Ø
OM – 3NWM 12 – 36 360 TWO STAGE 250 / 1Ø
OM – 4NWM 16 – 48 480 TWO STAGE 400 / 3Ø

Fuel Input Conditions:

  • Flooded suction
Model A B C D E F G
OM-0N φ88 100 360 314 290 135/150 8-11
OM-1N φ88 100 402 351 357 135/150 8-11
OM-2N φ114 120 490 366 390 185 8-12
OM-3N φ127 150 568 425 446 240 8-12
OM-4N φ140 150 568 425 446 240 8-12
OM-1NWM φ88 100 502 351 417 135/150 8-11
OM-2NWM φ114 120 592 366 450 185 8-12
OM-3NWM φ127 150 700 425 500 240 8-12
OM-4NWM φ140 150 700 425 500 240 8-12
Dimension Capacity Curve
Light Oil Burners - OM Series Dimension

Salient Features
  • Comes with electromagnetic (diaphragm) pump which can handle all light oils including low viscous oils like SKO / kerosene / C9 etc
  • High fan pressures – even at full loads pressure does not drop drastically
  • No return oil line from pump
  • Fan motor can be bypassed easily without any major change in the burner wiring / operation
  • Can be fixed in any orientation (360 deg)
Download Light Oil Burners - OM Series Brochure  Submit

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
TC – 10 2 – 4 40 ON-OFF 40 / 1Ø
TC – 20 3 – 6 60 ON-OFF 80 / 1Ø
TC – 30 4 – 8 80 ON-OFF 100 / 1Ø

Fuel Input Conditions:

  • Flooded suction
Dimension
Light Oil Burners - TC Series Dimension
Capacity Curve
Light Oil Burners - TC Series Capacity Curve

 

 

Download Light Oil Burners - OM Series Brochure  Submit

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
TC – 10 2 – 4 40 ON-OFF 40 / 1Ø
TC – 20 3 – 6 60 ON-OFF 80 / 1Ø
TC – 30 4 – 8 80 ON-OFF 100 / 1Ø

Fuel Input Conditions:

  • Flooded suction

 

 

Dimension
Light Oil Burners - TC Series Dimension
Capacity Curve
Light Oil Burners - TC Series Capacity Curve

 

Light Oil Burners – OM Series

This series comprises of small and medium sized burners that are being used for smaller equipment with a relatively high combustion chamber pressure.  This series has great freedom of installation position – horizontal, vertical or in other angles, and the burner head can be removed and reinstalled with ease to facilitate maintenance.

Salient Features
  • No return oil line (only one hose is used)
  • Solenoid valve with coil comes separately in the copper line. Thus minimizes replacement costs of spares
  • Pumps used are always kerosene compatible ones
  • Igniter is kept “on” for 16 seconds
  • High fan pressures – even at full loads pressure does not drop drastically
  • Oil hose and pressure gauge come along with the burner
  • Air lock removal valve is provided in the oil line
  • Fan motor can be bypassed easily without any major change in the burner wiring / operation
  • Diffuser is of SS
Download Light Oil Burners - OM Series Brochure  Submit

Specification
MODEL OUTPUT LPH OUTPUT KW CONTROL MOTOR WATT / PHASE
OM – 1N 4 – 12 120 ON -OFF 150 / 1Ø
OM – 2N 8 – 24 240 ON -OFF 250 / 1Ø
OM – 3N 12 – 36 360 ON -OFF 250 / 1Ø
OM – 4N 16 – 48 480 ON -OFF 400 / 3Ø
OM – 1NWM 4 – 12 120 TWO STAGE 150 / 1Ø
OM – 2NWM 8 – 24 240 TWO STAGE 250 / 1Ø
OM – 3NWM 12 – 36 360 TWO STAGE 250 / 1Ø
OM – 4NWM 16 – 48 480 TWO STAGE 400 / 3Ø

Fuel Input Conditions:

  • Flooded suction
Model A B C D E F G
OM-0N φ88 100 360 314 290 135/150 8-11
OM-1N φ88 100 402 351 357 135/150 8-11
OM-2N φ114 120 490 366 390 185 8-12
OM-3N φ127 150 568 425 446 240 8-12
OM-4N φ140 150 568 425 446 240 8-12
OM-1NWM φ88 100 502 351 417 135/150 8-11
OM-2NWM φ114 120 592 366 450 185 8-12
OM-3NWM φ127 150 700 425 500 240 8-12
OM-4NWM φ140 150 700 425 500 240 8-12
Dimension Capacity Curve
Light Oil Burners - OM Series Dimension
error: Content is protected !!